  "schema_version": "tt.research-slice-definition.v1",
  "slug": "pf-002",
  "programme": "Quaternion Pathfinder",
  "title": "Can two force sensors distinguish optical recoil from interference?",
  "question": "Which simulated instrument imperfections prevent reliable separation, and what would need to improve?",
  "environment": "Virtual lab - simulated experiment",
  "introduction": {
    "what": "A simulated light source changes between two phase settings. Two simulated force sensors are subtracted, and their force contrast is compared with a prediction from the outgoing light. No physical force was measured.",
    "why": "Light carries momentum, so an emitter feels a tiny backwards force: ordinary radiation recoil. An experiment must separate that signal from heat, vibration and sensor changes before attributing a reading to the source. A failed simulated control identifies a design limitation, not the limit of every possible design.",
    "title": "PF-002 studies the measurement apparatus for ordinary radiation recoil. The mechanistic robustness slice asks which imperfections limit that apparatus, not whether a new propulsion mechanism exists."
  },
  "objective": "Find what prevents the two-channel instrument distinguishing the predicted optical recoil from unwanted forces.",
  "goal": "Test a predeclared separation requirement with channel-envelope calculations, adverse controls and fresh simulated seeds; retain failures and unresolved explanations.",
  "diagram_caption": "Conceptual schematic, not to scale. Solid lines show model couplings; the dashed path is reference leakage. Numbered labels identify varied imperfections. In the orientation panel, the upper and lower arrows show opposite source orientations; dashed arrows identify the source-fixed impostor.",
  "diagram_explanation": "Phase-paired light drives the primary sensor and leaks partly into the reference sensor. Their weighted difference is compared with a finite detector prediction in one measurement domain. A shared disturbance cancels only if channel balance stays sufficiently stable. Recoil reverses when the source turns around; a laboratory-fixed force does not, but a source-fixed impostor reverses too and cannot be separated here.",
  "facts_explanation": "A margin is the separation remaining after the model's error allowance. Positive margins clear a model requirement only when the other controls and truth audits also hold. A piconewton (pN) is one trillionth of a newton. Values below use the retained tier-B analysis; force values are rounded to two decimal places in pN, while downloads preserve full precision.",
  "overview": "The original coupled comparison looked successful, but it compared force and optical intervals in different measurement domains. Correcting that in version 2 left the force-decoupled control rejected in only five of eight seeds. That is the retained negative result, not an apparatus success. The later robustness study explains the limitation: changes in sensor gain and subtraction weight that follow the phase labels leak the larger shared disturbance into the signal.",
  "interpretation": "Better read noise alone does not restore a worst-case margin in this model. Better-known or steadier channel balance can, at assumed levels. The all-improved configuration clears the predeclared requirement conditionally; it does not overturn the earlier negative result, because it changes the assumed apparatus. Turning the source around distinguishes a laboratory-fixed impostor, but a force that reverses with the source remains indistinguishable from recoil. A resolved contrast is therefore not attribution to optical recoil.",
  "limitations": [
    "All equipment levels are assumed, not measured calibrations. This low-order instrument class is not a hardware twin.",
    "The optical window is a numerical lattice with a remainder, not a proof. Channel bounds apply only inside the declared model and parameter box.",
    "The structural allowance for omitted effects is unsupported. Real systematic effects could overwhelm the conditional margins.",
    "Phase and feed mismatch is constant within each trial. No within-trial fluctuation, measured spectrum, hysteresis, saturation, nonlinear transduction or quantisation was simulated.",
    "Source-fixed impostors remain non-identifiable. No physical recoil, modified inertia, new field, propulsion capability or spacecraft performance is established.",
    "The failed first exploratory run and historical version-1 evidence remain retained. Their original bytes are not corrected in place."
  ],
  "next_step": "Predeclare the candidate stationarity requirement and detector-loss study. Continue virtual qualification with explicitly bounded imperfections; physical validation remains a separate evidence class, not a prerequisite for the next virtual study.",
  "forward_paths": [
    {"limitation": "Changes in channel balance can turn a shared disturbance into an apparent signal.", "proposal": "Test whether a better constrained or more stable channel balance can support reliable separation without assuming every apparatus property improves together.", "test": "Predeclare a stationarity study with independent checks, adverse controls and an explicit accounting of omitted effects before running new virtual trials.", "disconfirming_result": "The candidate stationarity condition fails if permitted disturbances still defeat the predeclared separation requirement or an independent check invalidates the model account.", "source": "experiments/pf-001/PF002_MECHANISTIC_ROBUSTNESS_V1_RESULTS.md"},
    {"limitation": "The frozen detector window loses useful signal, while a source-fixed impostor remains indistinguishable in the present observations.", "proposal": "Explore detector-loss alternatives and separately seek an additional observable or control that could distinguish source-fixed forces. Do not assume improved sensitivity resolves attribution.", "test": "Write separate bounded protocols for detector-loss alternatives and any proposed distinguishing observable, retaining both source orientations and adverse impostor controls.", "disconfirming_result": "Reject an attribution proposal if the impostor and recoil remain observationally identical; reject a detector alternative if it fails its frozen requirement. Neither result decides an independent new-mechanism hypothesis.", "source": "experiments/pf-001/PF002_MECHANISTIC_ROBUSTNESS_V1_RESULTS.md"}
  ],
  "sources": [
    {"path": "experiments/pf-001/pf002-mechanistic-robustness-v1.json", "role": "result", "label": "Confirmatory robustness record"},
    {"path": "experiments/pf-001/pf002-mechanistic-robustness-v1-exploratory.json", "role": "result", "label": "Exploratory sensitivity record"},
    {"path": "experiments/pf-001/pf002-mechanistic-robustness-v1-exploratory-run1.json", "role": "explanation", "label": "Failed first exploratory run, preserved"},
    {"path": "experiments/pf-001/coupled-differential-optical-v2.json", "role": "result", "label": "Corrected coupled experiment: negative result"},
    {"path": "experiments/pf-001/coupled-differential-optical-v1.json", "role": "explanation", "label": "Historical version 1, superseded comparison"},
    {"path": "experiments/pf-001/PF002_MECHANISTIC_ROBUSTNESS_V1.md", "role": "protocol", "label": "Frozen protocol and declared amendments"},
    {"path": "experiments/pf-001/PF002_MECHANISTIC_ROBUSTNESS_V1_RESULTS.md", "role": "explanation", "label": "Full research interpretation and limits"},
    {"path": "experiments/pf-001/PF002_MECHANISTIC_ROBUSTNESS_V1_CORRECTIONS.md", "role": "explanation", "label": "Fidelity and runtime corrections"},
    {"path": "experiments/pf-001/pf002-mechanistic-robustness-v1.svg", "role": "diagram", "label": "Source-linked setup, objective and goal schematic"}
  ],
  "facts": [
    {"id": "coupled-rejection", "label": "Version 2 force-decoupled controls rejected", "source": "experiments/pf-001/coupled-differential-optical-v2.json", "pointer": "/primary/controls/force-decoupled/matched", "unit": "count"},
    {"id": "coupled-total", "label": "Version 2 force-decoupled controls tested", "source": "experiments/pf-001/coupled-differential-optical-v2.json", "pointer": "/primary/controls/force-decoupled/total", "unit": "count"},
    {"id": "coupled-outcome", "label": "Version 2 retained outcome", "source": "experiments/pf-001/coupled-differential-optical-v2.json", "pointer": "/primary/outcome", "unit": ""},
    {"id": "requirement", "label": "Predeclared minimum margin", "source": "experiments/pf-001/pf002-mechanistic-robustness-v1.json", "pointer": "/required_margin_newtons", "unit": "N"},
    {"id": "baseline-null", "label": "Baseline worst-case control margin", "source": "experiments/pf-001/pf002-mechanistic-robustness-v1.json", "pointer": "/configurations/0/design/tiers/B/null_margin_newtons", "unit": "N"},
    {"id": "baseline-signal", "label": "Baseline worst-case signal margin", "source": "experiments/pf-001/pf002-mechanistic-robustness-v1.json", "pointer": "/configurations/0/design/tiers/B/signal_margin_newtons", "unit": "N"},
    {"id": "improved-null", "label": "All-improved worst-case control margin", "source": "experiments/pf-001/pf002-mechanistic-robustness-v1.json", "pointer": "/configurations/7/design/tiers/B/null_margin_newtons", "unit": "N"},
    {"id": "improved-signal", "label": "All-improved worst-case signal margin", "source": "experiments/pf-001/pf002-mechanistic-robustness-v1.json", "pointer": "/configurations/7/design/tiers/B/signal_margin_newtons", "unit": "N"},
    {"id": "improved-outcome", "label": "All-improved retained tier-B outcome", "source": "experiments/pf-001/pf002-mechanistic-robustness-v1.json", "pointer": "/outcomes/all/B", "unit": ""}
  ]
}